Refine
Keywords
- Bowen ratio method (1)
- Bowen-Verhältnis-Methode (1)
- Meteorologie (1)
-
Error analysis of the modified Bowen ratio method
(1999)
- The sensible and latent heat fluxes are obtained, using the modified Bowen ratio method (MBR) and Bowen ratiolEnergy balance method (BREB) with the data of LINEX-97/l and LITFASS-1998 experiments. The error analysis of MBR and the error comparisons between both methods are also made in detail by a lot of numerical experiments and the measured data. The results illustrate that the MBR, compared with the BREB, can obtain higher accurate results with errors of less than ±lO% for sensible heat flux and less than ±20% for latent heat flux.