Error analysis of the modified Bowen ratio method
The sensible and latent heat fluxes are obtained, using the modified Bowen ratio method (MBR) and Bowen ratiolEnergy balance method (BREB) with the data of LINEX-97/l and LITFASS-1998 experiments. The error analysis of MBR and the error comparisons between both methods are also made in detail by a lot of numerical experiments and the measured data. The results illustrate that the MBR, compared with the BREB, can obtain higher accurate results with errors of less than ±lO% for sensible heat flux The sensible and latent heat fluxes are obtained, using the modified Bowen ratio method (MBR) and Bowen ratiolEnergy balance method (BREB) with the data of LINEX-97/l and LITFASS-1998 experiments. The error analysis of MBR and the error comparisons between both methods are also made in detail by a lot of numerical experiments and the measured data. The results illustrate that the MBR, compared with the BREB, can obtain higher accurate results with errors of less than ±lO% for sensible heat flux and less than ±20% for latent heat flux.…



| Institutes: | Geowissenschaften |
|---|---|
| Author: | Heping Lui |
| Creating Corporation: | Universität Bayreuth, Abteilung Mikrometeorologie |
| Year of Completion: | 1999 |
| Series (Volume number) | Arbeitsergebnisse / Universität Bayreuth, Abteilung Mikrometeorologie (4) |
| SWD-Keyword: | Meteorologie |
| Tag: | Bowen-Verhältnis-Methode Bowen ratio method |
| Dewey Decimal Classification: | 550 Geowissenschaften |
| RVK - Regensburg Classification: | TA |
| URN: | urn:nbn:de:bvb:703-opus-7736 |
| Document Type: | Report |
| Language: | English |
| Date of Publication (online): | 03.02.2011 |